Search or add a thesis

Advanced Search (Beta)
Home > Maternal Motivation, Psychological Well-Being and Behavioral Problem of Children With Intellectual Disability

Maternal Motivation, Psychological Well-Being and Behavioral Problem of Children With Intellectual Disability

Thesis Info

Author

Shamila Irum

Supervisor

Rabia Jameel

Program

MS

Institute

Riphah International University

Institute Type

Private

City

Lahore

Province

Punjab

Country

Pakistan

Thesis Completing Year

2018

Thesis Completion Status

Completed

Page

xii, 62 . ; 30 cm. +CD : ill.

Language

English

Other

Submitted in partial fulfillment of the requirements for the degree of MS in Clinical Psychology; Includes references.; Thesis (MS Clinical psychology)-Riphah International University, 2018; English; Call No: SHA 150

Added

2021-02-17 19:49:13

Modified

2023-01-06 19:20:37

ARI ID

1676711676863

Similar


Loading...
Loading...

Similar Books

Loading...

Similar Chapters

Loading...

Similar News

Loading...

Similar Articles

Loading...

Similar Article Headings

Loading...

علامہ اخلاق حسین دہلوی

سیداخلاق حسین دہلوی
شمع اردو کاایک اورچراغ بُجھ گیا،اردو کے ممتاز اہل قلم اورادیب ونقاد علامہ سید اخلاق حسین دہلوی اپنی رہائش گاہ لال محل بستی حضرت نظام الدین نئی دہلی میں تقریباً چھ ماہ کی علالت سے گذرتے ہوئے اٹھاسی سال کی طبعی عمر میں انتقال فرماکر اپنے مولیٰ کے حضور میں حاضر ہوگئے۔انا ﷲ وانا الیہ راجعون ۔
مرحوم انتہائی دیندار اوربلند پایہ کتابوں کے مصنف تھے ان کی سوانح عمری میں یہ مرقوم ہے کہ انہوں نے ۱۶ سال کی عمر میں ایک تحقیقی کتابچہ ’’عشق ‘‘ مرتب کرکے شائع کیاتھا۔ اس کے بعدتوان کی کئی کتابیں منظر عام پر آکرعلمی دینی اور ادبی حلقوں میں داد تحسین حاصل کرگئیں۔ ’ ویدک دھرم اور اسلام‘ ان کی کتاب علمی اورتاریخی دنیا میں بڑی شہرت وسراہت کاباعث بنی۔
حضرت علامہ سید اخلاق حسین دہلوی کوعلماء کرام سے بڑی ہی عقیدت تھی، مفکر ملّت حضرت مفتی عتیق الرحمن عثمانیؒ سے انہیں والہانہ لگاؤ وانسیت اور محبت تھی، اکثر ادارہ ندوۃ المصنفین دہلی کے دفتر میں مفتی صاحب ؒ سے ملاقات کی غرض سے آتے اور بڑی دلجمعی کے ساتھ ان کے خیالات سے استفادہ کرتے، مجاہد ملّت حضرت مولانا حفظ الرحمن ؒ اورسحبان الہند مولانا احمدسعیدؒ سے بھی ان کا خصوصی تعلق وربط تھا۔
دہلی کی تہذیب وتمدن کی نمائندگی کے جیتے جاگتے نمونہ تھے۔آہ !ایسی زندہ دل، متین ومخلص شخصیت بھی اب ہمارے درمیان سے اٹھ گئی:
’’اب اسے ڈھونڈ چراغ رخِ زیبا لے کر‘‘
مرحوم علامہ سیداخلاق حسین دہلوی ملّی کاموں میں بھی پیش پیش رہتے تھے۔ ان کے برادرِ خوردحکیم سید حسین دہلوی جن کا انتقال تقریباً ڈیڑھ دوسال پیشتر اپنے برادرِ کلاں کی حیات میں ہی ہوگیاتھا۔دہلی کی معاشرتی اورادبی زندگی کی جان تھے۔خلوص وایثار کے پیکر مجسم!
اﷲ تعالیٰ کروٹ کروٹ جنت نصیب فرمائے اورمتعلقین کوصبر جمیل عطا کرے...

Justice System of Islam in the Form of Qisas, Diyat and Harabah for the Protection of Human Dignity

For peace in a society and to protect the lives and properties of all the individuals living in a society, it is necessary that there must be certain rules and regulations that govern the whole system of society.  A guideline for each and every aspect of human life should be there. For this purpose Islamic law or Shariah law took origin to govern an Islamic state and for avoiding injustice and to preserve human dignity Shariah law prescribes different forms of punishment which constitute the basic criminal justice system of Islam. These include Qisas, Diyat and Harabah. Thus, the Quran not only specifies principles of retaliation in the form of Qisas but also gives an option of monetary compensation (blood money Diyat) to the aggrieved family of the victim. The fear of the consequences in the form of punishments prescribed by the Shariah Law must be there in a person's mind before he commits a crime and this fear will abstain from violating human dignity by destroying his life and property.

Evaluation of Dosimetric Properties in External Beam Radiation Therapy

A great level of accuracy and efficiency is required to execute the various paradigms of the radiotherapy processes. The work described in the dissertation was aimed to verify the quality of treatment plans for different techniques in order to enhance the accuracy of planning processes involved. Also dose profile uniformity was verified to improve the Quality Assurance (QA) of radiotherapy process.This project was organized into three major components comprising of ‘comparison of treatment plan quality of RapidArc and Intensity Modulated Radiotherapy (IMRT) using various dosimetric indices’, ‘investigation oftolerance dose to Organs at Risk (OARs) and assessing degree of homogeneity and conformity for Head and Neck (H&N) cancer patients by using Simultaneous Integrated Boost Intensity Modulated Radiotherapy (SIB IMRT) technique’, and ‘determination of quality of 6 MV and 15 MV wedge-shaped radiation beams by analyzing the effect of symmetry parameter on depth, field size, beam energy, and wedge angle.’ First, analysis and comparison of the plan quality of IMRT and RapidArc techniques using various dosimetric indices was carried out to find out the better treatment modality for treating patients with cervix cancer. Thirteen cervical cancer patients treated with IMRT were selected for analysis and original plans were subsequently re-optimized based on the RapidArc technique. Inverse treatment planning was done by Eclipse (Varian Medical Systems, Palo Alto, CA) Treatment Planning System (TPS) for 15 MV photon beams from computed tomographic data. Double arcs were used for RapidArc plans. Quality of treatment plans were evaluated by calculating Conformity Index (CI), Homogeneity Index (HI), Gradient Index (GI), coverage, and Unified Dosimetry Index (UDI) for each plan. RapidArc plans resulted in better Planning Target Volume (PTV) coverage as evident by its superior Conformation Number (CN), coverage, CI, HI, GI, and UDI. Regarding Organs at Risk, RapidArc plans exhibit superior organ sparing as found from integral dose comparison. Difference between both techniques was determined by statistical analysis. For all cases under study, modest differences between IMRT and RapidArc treatment were observed. In conclusion, RapidArc-based treatment planning is safer with similar planning goals compared to the standard fixed IMRT technique. Furthermore, degree of conformity, homogeneity and tolerance dose to organs at risk for head and neck cancer patients were investigated. Fifteen patients receiving treatment based on inverse planned SIB IMRT technique were analyzed in this study. Using a beam energy of 6 MV, two dose levels of 70 Gy and 55·4 Gy were used to treat the tumor. Doses of 2 Gy in 35 fractions and 1·68 Gy in 33 fractions were simultaneously delivered for Effective Planning Target Volume (PTV1) and Boost Planning Target Volume (PTV2) respectively. Dose distribution in PTV and critical organs lie within tolerance dose guidelines protecting spinal cord, brain stem, optic chiasm, and optic nerve. Minor deviation from tolerance limit was observed for parotid glands. This technique provided highly conformal and homogenous dose distribution as well as offered best solution for preserving organ function by keeping dose below tolerance level. Finally, symmetry parameter of wedge-shaped photon beam profile was investigated to determine quality of radiation beams produced by linear accelerator. Analysis of beam profile parameter symmetry was performed for 6 MV and 15 MV photon beam energies by varying different factors such as depth, field size and wedge angle. Photon beam profile was measured from Varian’s Clinac DHX using PTW array detector. Data management, analysis, and processing of isodose curves was carried out by PTW MP3-M water tank and PTW MEPHYSTO version 7.33 software. Variation in symmetry was analyzed to match acceptance criteria as recommended by the American Association of Physicists in Medicine (AAPM) protocols. Results implied that symmetry parameter can be treated as being independent of depth and linearly increase with field size and wedge angle. For wedged beam profiles, measured values of symmetry were generally good and exceeded only slightly from the AAPM’s standard criteria for symmetry for open fields. The difference between open field beam profiles and wedge-shaped profiles were considered so that possible errors involved in radiotherapy process can be rectified.