Production of radioactive scandium by irradiating natural titanium metal in Pakistan Research Reactor-1 was evaluated. The production rate of scandium-47 ( 47 Sc) and other radioactive scandium was estimated. High specific activity 47 Sc can be produced by irradiating enriched titanium-47 in sufficient quantities needed for therapeutic applications. A new separation technique based on column chromatography was developed. Neutron irradiated titanium was dissolved in hydrofluoric acid, which was evaporated and taken in distilled water. The resulting solution was loaded on silica gel column. The radioactive scandium comes out first and the inactive titanium is removed with 2 M HCl. More than 95% radioactive scandium was recovered, while chemical impurity of titanium determined by optical emission spectroscopy was less than 0.01 μg / mL in final product of 47 Sc. Production of Copper-64 ( 64 Cu) by irradiating copper and zinc metals in a reactor was evaluated. Low specific activity 64 Cu can be easily produced using thermal neutrons via 63 Cu (n, γ) 64 Cu reaction, while use of fast neutrons are mandatory for high specific activity 64 Cu via 64 Zn (n, p) 64 Cu reaction. Natural copper and zinc targets were irradiated in Pakistan Research Reactor-1. Radionuclidic impurities produced by thermal and fast neutrons were determined. Commonly available organic anion exchange resin (AG 1-X8) was used for the separation of no-carrier-added radiocopper from neutron irradiated zinc. More than 95 % 64,67 Cu was recovered. The radionuclidic and chemical purity of 64 Cu was determined. The specific activity of 64 Cu produced by 63 Cu (n, γ) and 64 Zn (n, p) was compared.The metallic cation, 68 Ga (III) is suitable for complexation with chelators either naked or conjugated with biological macromolecules, however, such labeling procedure requires high chemical purity and concentrated solutions of 68 Ga (III), which cannot be sufficiently fulfilled by the presently available 68 Ge/ 68 Ga generator eluate. A method to increase the concentration and purity of generator has been developed. The 68 Ga obtained from a commercial 68 Ge/ 68 Ga 68 Ga eluate (1M HCl) is extracted in methyl ethyl ketone, which is evaporated and taken in a small volume of buffer. Arsenic-77 (T 1/2 = 1.6 d) was produced by irradiating natural germanium in Pakistan Research Reactor-1. The nuclear reaction 76 Ge (n, γ) produces 77 Ge, which decays by emission of β - particles into 77 As. The neutron irradiated target was dissolved in aqua regia, excess of acid was removed by evaporation and finally the solution in basic media was passed through hydrous zirconium oxide (HZO) column. The Ge was quantitatively retained on HZO, while 77 As was present in the effluent. More than 90 % 77 As was recovered. The chemical impurity of Ge in 77 As was <0.01μg/mL. Large columns containing aluminum oxide (Al 2 O 3 ) or gel (e.g. zirconium molybdate) are needed to prepare 98 Mo(n,γ) 99 Mo→ 99m Tc column chromatographic generators that results in large elution volumes containing relatively high 99 Mo impurity and low concentrations of 99m Tc. Post elution concentration of 99m Tc using in house prepared lead cation exchange and alumina column was developed. The principle of the method developed is trapping of anionic pertechnetate on tiny alumina column. This can be only achieved in the absence of sulfate ions. These sulfate ions are removed from the eluate by reaction with lead ions loaded onto a cation exchange column, to precipitate lead sulfate, which is filtered out by the column packing. Using these columns high bolusvolumes (10-60 ml 0.02 M sodium sulfate) of 99m Tc can conveniently be concentrated in 1 mL of physiological saline. This approach also works very effectively to prepare high specific volume solutions of 99m Tc-pertechnetate from a fission based 99 Mo/ 99m Tc generator in the second week of its normal working life. Rhenium-188 is also obtained from alumina based 188 W→ 188 Re generator, and developed technique can also be used for the concentration of 188 Re. Because of the high content of inactive molybdenum in neutron irradiated MoO 3 , large columns containing alumina or gel are needed to produce chromatographic 99 Mo→ 99m Tc generator. This results in large elution volumes containing relatively high 99 Mo breakthrough and low concentrations of of 99m 99m TcO 4- . The decrease in specific volume Tc places a limitation on reconstitution of some kits for 99m Tc radiopharmaceuticals applied in diagnostic nuclear medicine. Hence concentration technique is mandatory for effective utilization of (n,γ) produced 99 Mo/ 99m Tc generators at the start of its life whereas in case of fission 99 Mo/ 99m Tc generator the technique may be quite useful at the end of first week of its life. Post elution concentration of 99m Tc using in house prepared lead (Pb) column was developed. The high bolus volumes (10-60 ml saline) can conveniently be concentrated in ~1 ml of saline. The adsorption behavior of Na 188 ReO 4 is quite different from Na 99m TcO 4 on lead column. Sodium perrhenate did not adsorb on Lead column and found quantitatively in effluent. Thus Lead column may also be used for the separation of Na 99m TcO 4 from Na 188 ReO 4 . The high bolus volumes (20–40 mL) of the generator-produced Rhenium-188 require post elution concentration of the eluate for the preparation of a dissolved β − source and radiopharmaceuticals labeled with Re-188 for radiotherapy. Solvent extractionof 188 Re in methyl ethyl ketone was studied. With the increase of organic phase volume, extraction of 188 Re was enhanced while mixing time of aqueous and organic phases did not show any significant effect on the extractability of 80% of 188 Re in the organic phase. Almost 188 Re was extracted in methyl ethyl ketone at a volume ratio of 1 : 2 for aqueous and organic phases. By evaporation/distillation of methyl ethyl ketone, concentrated and dissolved in the desired volume of physiological saline.
Objective: The purpose of this study is to evaluate the difference at occupational performance skills related to visual perception among typical developing children and cerebral palsy children by using measuring test of MVPT-R.
Design And Sampling Technique: Quantitative cross-sectional study, convenience sampling method.
Study Setting And Participants: A total of 400 Cerebral palsy children (all types) and typical children each from different mainstream schools, rehab centers, pediatric occupational therapy departments, and special education centers located in Karachi.
Interventions / Data Collection: Test of visual perception that is Motor Free visual perceptual test- Revised MVPT-R.
Result: Result shows difference in perceptual ages (PA) between typical and cerebral palsy children. Perceptual age (PA) was greater than the chronological age (CA) in the typical group. Conversely, in the CP group the perceptual age (PA) was lesser than the chronological age (CA).
Conclusion: Visual perception skills play a key role in a child’s achievement at school and at home. Children require intact visual perception for the successful performance of their daily living as well as academic tasks like good eye-hand coordination, handwriting, reading, shape perception, play skills, and copying patterns, etc. This study is helpful to identify those children who have visual perception issues and sorting this problem will form the baseline for better evaluating and planning of useful visual perception activities for typical and cerebral palsy children.
Water resources development and management acquired new dimensions in Pakistan. Recently, the Government of Pakistan has taken strategic initiatives and primarily focused on governance, decentralization and participation of the farmers by transforming the Provincial Irrigation Department (PID) to the Frontier Irrigation and Drainage Authority (FIDA). Management responsibilities are decentralized at canal command level to Area Water Boards (AWBs) and most of the existing functions at distributary level are performed by the farmer’s organizations (FOs). Recently six distributaries have been handed over to the farmer organizations under the irrigation management transfer (IMT) programme in Swat Canal Area Water Board (SCAWB). The study was conducted to analyse the operational performance using hydraulic simulation modeling. To assess the impact of IMT on the performance of the irrigation system a database oriented irrigation management information system (IMIS) technique has been developed and utilized. The Simulation of Irrigation Canal (SIC) hydrodynamic model was used to analyse the improved operational scenarios for the irrigation systems operation at distributary level, to provide the system managers and farmers organizations to update the managerial control and plan operational activities through improved understanding of the system. Results of the study revealed that irrigation supplies are in excess of the crop water requirements. The relative water supply (RWS) index varies from 1.66 to 2.02 during summer, whereas in winter it varies from 2.22 to 2.55. The delivery performance ratio (DPR) during summer varies from 0.78 to 0.83 and in winter from 0.63 to 0.73. Irrigation supplies were reliable over the whole growing season. Due to modernization of the irrigation systems and enhanced water allowance, the annual cropping intensity and yield have increased significantly. There is a prominent increase in yield of maize (40 percent), sugarcane (55 percent) and wheat (43 percent) while the cropping intensity has increased by 25 percent. iv The Irrigation service fee (ISF) collection analysis indicated that all the FOs performed well during the first year (2004-05) of IMT and recovered 60 percent of the assessed ISF; whereas during the 2005-06 and 2006-07, ISF collected was very low. From these results it is evident that chances of successful cost recovery do not seem to be high. Operational and regulation aspects of the main system also play a pivotal role in overall irrigation water management aspects. The SIC model was used to evaluate the effectiveness of physical infrastructures of the Chowki Distributary. Open flume outlets along the distributary behave as hyper-proportional irrespective of their position. The head bifurcator outlets are behaving hyper-proportional, whereas middle ones as perfect proportional and tail end as sub-proportional. The trifurcator outlets are behaving as hyper-proportional. The major causes are construction inaccuracies in setting the crest level, which lead the outlets to draw more or less than the design discharge. To improve the manual operation of the Chowki Distributary irrigation system, different operational strategies were investigated and quantified. From the results of this study, it is suggested to operate the distributary head regulator manually based on fixed frequency operation. It is recommended that from May to July, the distributary should be operated at 90-80 percent of design discharge, 90-75 percent of design discharge from August to October and 75-85 percent of design discharge from December to April to adjust the over delivery due to high water allowance. Hydraulic committees at each of the distributary should be established to operate the distributary according to crop demand. Awareness among the farmers should be created regarding the farm irrigation application methods to avoid over-irrigation and wastage of water.