Search or add a thesis

Advanced Search (Beta)
Home > Synthesis and Characterization of Polyurethane Acrylate Copolymers

Synthesis and Characterization of Polyurethane Acrylate Copolymers

Thesis Info

Access Option

External Link

Author

Sultan, Misbah

Program

PhD

Institute

University of Agriculture

City

Faisalabad

Province

Punjab

Country

Pakistan

Thesis Completing Year

2011

Thesis Completion Status

Completed

Subject

Chemistry

Language

English

Link

http://prr.hec.gov.pk/jspui/handle/123456789/1946

Added

2021-02-17 19:49:13

Modified

2024-03-24 20:25:49

ARI ID

1676727462580

Asian Research Index Whatsapp Chanel
Asian Research Index Whatsapp Chanel

Join our Whatsapp Channel to get regular updates.

Similar


In this modern era, a world without synthetic polymers is incredible. In spectacle of rapidly depleting natural resources, synthetic polymers have become an elegant alternative. Polyurethanes are one of these, that have been developed as an exclusive class of polymers with wide variety of applications in foams, elastomers, coatings, sealants, textile finishing, automotive, insulation and footwear industries. Polyurethane based coating systems have a proven record in the coatings industry dominating the market in some applications because they exhibit a high level of quality. These coatings allow high variability of the property profile and can be fitted for a specific application by changing, the chemical structure of the constituents or the molecular weight and degree of branching of the chains. Polyurethane coatings are in general more expensive. Polyurethane chemistry permits the amalgamation of functional groups which can be used to modify properties. To take advantage of polyurethane film-forming properties, a combination with cheaper materials is now a common practice in the coating market, leading to new different products. Of the most popular second components, one is the acrylic dispersion and the new product combines the excellent mechanical and chemical properties of the polyurethane resin with the low price of the acrylic component. In current project polyurethane coatings were prepared by the copolymerization of polyurethane with the butyl acrylate. Different series of polyurethane acrylate copolymers containing different monomeric constituents i.e. diisocyanates and polyols, in different proportions with butyl acrylate were synthesized by emulsion polymerization and characterized successfully. The synthesis of these copolymers was completed in three steps i.e. synthesis of polyurethane prepolymers, introduction of unsaturated sites at the free reactive ends of polyurethane prepolymers and copolymerization of vinyl terminated polyurethane prepolymers with n-butyl acrylate. Also, these copolymers were applied on textile fabric as finishing agent and their effect was assessed by different standard textile tests.
Loading...
Loading...

Similar Books

Loading...

Similar Chapters

Loading...

Similar News

Loading...

Similar Articles

Loading...

Similar Article Headings

Loading...

مولانا محمد جلیل کیرانوی

مولانا محمد جلیل کیرانوی
افسوس ہے کہ گزشتہ ماہ اگست میں حضرت شیخ الہندؒ کے دومنتسبین،مولانا محمد جلیل کیرانوی استاذ اورمولانا محمد مبارک علی نائب مہتمم دارالعلوم دیوبند واصل بحق ہوکر اس جہانِ فانی کوالوداع کہہ گئے۔اناﷲ وانا الیہ راجعون۔ اوّل الذکر (المتولد۱۳۱۸ھ)نے اگرچہ دورۂ حدیث حضرت الاستاذ مولانا محمد انورشاہ کے عہد میں تمام کیا تھا لیکن درحقیقت پروردہ تھے حضرت شیخ الہند کے گھرانے کے ہی۔ نوبرس کی عمر تھی کہ اُن کے والد حضرت ؒ کے سپردکرگئے تھے۔یہ اس آستانۂ قدس کوایسے چمٹے کہ مرتے دم تک اسے نہ چھوڑا۔اس لیے حضرت شیخ الہند کے خادم خاص اور شریکِ جلوت وخلوت تھے اس بناء پر حضرت شیخ الہند کی مشہور’’ریشمی خطوط‘‘والی تحریک کے جزوکل سے خوب واقف اوراس کے محرمِ اسرار تھے۔اس سلسلہ میں انھوں نے بڑے بڑے مصائب اورشدائد برداشت کئے لیکن تحریک کابھید آشکار نہیں کیا۔حضرت ؒ کی وفات کے بعد ادہر ادہرمدرس رہے۔آخر میں دیوبند آگئے تھے اوردرس کی خدمات انجام دیتے تھے۔
[ستمبر۱۹۶۸ء]

 

Spatial-Temporal Analysis the Dynamics of Changes on the Foreign Exchange Market: An Empirical Estimates from Ukraine

The foreign exchange market plays an important role in the formation and development of financial markets. This market is of particular importance for emerging economies. To understand market trends (to understand and develop a strategy for its development), it is necessary to analyze historical data. It is also important to use different methods to carry out this analysis. Based on this, the paper analyzes the foreign exchange market in Ukraine for the period 2014-2018. For this analysis, the wavelet coherence methodology is used. This made it possible to assess the development of the foreign exchange market in Ukraine.

Clinical Implementation of Volumetric Modulated Arc Therapy Vmat and Image Guided Radiotherapy Igrt Techniques

Volumetric Modulated Arc Therapy is a novel treatment delivery technique, used to deliver intensity modulated radiotherapy (IMRT) fluences in dynamic-arc-mode around the patient. VMAT has gained the attention due to its ability to produce complex dose distributions and delivery in much shorter treatment time than conventional IMRT technique. The optimum VMAT dose distributions and efficient delivery depend on the choice of optimization algorithm, user selectable planning parameters and treatment delivery equipment. Many authors reported VMAT studies for conventional Linac equipped with 40 × 40 cm² apertures. This study intended in the search for optimal user selectable VMAT planning parameters for a Linac equipped with the ''Beam-Modulator™'' with limited aperture of 21 × 16 cm². Geometric errors induced by inter- and intra- fraction motion may compromise the quality of radiation therapy treatments. Organ motion is a large contributor to treatment uncertainties in radiation therapy which can detrimentally affect the accuracy of treatment dose delivery. There have been many strategies in treatment planning, delivery and online imaging that account for organ motion to reduce effects on delivered doses. The multileaf collimator (MLC) tracking is one of the real-time adaptation techniques, that adapt treatment-beam to the target motion in real-time. We have, therefore, undertaken our studies to bring improvements in the areas of radiation treatment planning and image guidance for the better treatment of the patients. Our studies had been divided into three parts. In the first study, validation of the relative insensitivity of volumetric modulated arc therapy (VMAT) plan quality to gantry angle spacing (GS) was investigated. A quantitative comparison of dose–volume indices (DIs) was made for partial-arc (PA), single-arc (SA) and dual-arc (DA) VMAT plans optimized for 2°, 3° and 4° gantry angle spacing, representing a large variation of deliverable MLC segments. VMAT plans of six prostate cancer and six head-and-neck cancer patients were simulated. All optimization techniques generated clinically acceptable VMAT plans, except single-arc for the headand- neck cancer patients. A GS of 2°, with finest resolution was considered being reference, and was compared with GS 3° and 4°. The differences between the majority of reference and compared DIs were <2%. The metrics, such as treatment plan optimization xvii time and pre-treatment (phantom) dosimetric calculation time, supported the use of a GS of 4°. Therefore a GS of 4° is an optimal choice for minimal usage of planning resources without compromising plan quality. In the second study, dosimetric comparison of VMAT planning techniques and influence of collimator rotation on plan quality was investigated using a collimation system, limited to a maximum field size of 21 × 16 cm² (SynergyS® linear accelerator equipped with Beam Modulator™). A VMAT planning study of fifteen prostate and ten head and neck cancer patients was carried out. Single-arc, dual-arc and two combined independent-single-arcs (ISAs) VMAT techniques were optimized for four collimator angles; .C0°, C15°, C45° and C90° for prostate and C15°, C30°, C45° and C90° for head-and-neck. DA and ISAs provided similar PTV coverage, while DA provided better sparing of organs at risk, and similar treatment delivery times were noted for DA and ISAs techniques. In case of prostate optimizations similar target coverage for C0°, C15°, and C45° is noted, however C45° spared more rectum volumes than rest of collimator angles. A rotation of C45° provided significantly better target coverage and sparing of OARs than a rotation of C90°. In case of head-and-neck optimizations clinically acceptable dose distribution was calculated, and very similar target coverage for C30° and C45° is noted, however C45° spared more OARs volumes than rest of collimator angles. A single arc for the treatment of complex tumor sites like head-and-neck is not feasible while using limited aperture collimation (Beam Modulator™). None of the VMAT techniques optimized at C90° could achieve the defined treatment planning objectives. Thus, an optimal choice of VMAT arc and collimator angle is another degree of freedom to obtain desired PTV dose distributions and sparing of organs at risk. In the third study using prostate VMAT plans, a novel method of dynamic collimator rotation for improved multileaf collimator tracking was investigated. In the first step, two dual arc VMAT plans, one with fixed collimators (45° and 315°) and second with a rotating collimator were optimized for 22 prostate cancer patients. In the second step largescale MLC tracking simulations were done (using 695 motion traces) for all optimized VMAT plans, and thereafter dose reconstruction was performed for 35 motion traces for one patient, and the calculated root-mean-square dose error was compared with the MLC xviii exposure error. Rotating collimator VMAT plans were of similar quality as the fixed collimator plans, but significantly improved MLC tracking with 33% lower MLC exposure errors (p<<0.0001). The reductions in MLC exposure error correlated significantly with dose error reductions. Therefore MLC tracking with rotating collimator were significantly better than fixed collimator and agreement between planned and delivered dose distribution was higher for rotating collimator compared to fixed collimator. Hence, this study provided the improved methods for target dose distribution with optimal sparing of organs at risk, and accurate radiation dose delivery to the moving targets.